Type: | Ceramic Heating Equipment |
---|---|
Structure: | Vertical Type |
Brand: | Hiq |
Max.Temperature: | 1300c |
Heating Element: | Sic Heaters |
Thermocouple: | K Type |
Customization: |
---|
Suppliers with verified business licenses
Model No. | HIQ-1-10 | HIQ-8-12 | HIQ-18-12 | HIQ-30-12 |
Chamber Size | 100x100x100mm | 200x300x120mm | 250x300x250mm | 300x500x200mm |
Power Supply | 220V/1.2KW | 220V/2.5KW | 220V/6KW | 380V/7.5KW |
Furnace Type | Benchtop, flap door | |||
Usage | General purpose furnace ideal for general laboratory uses-gravimetric analysis, sintering, quantitative analysis and heat treatment | |||
Furnace Structure | 1. The furnace is consist of heating system, gas system, vacuum system 2. chamber is consist of chamber material, insulation material heating elements and atmosphere boxes 3. Temperature controller is consist of temperature PID controller, control elements and thermocouple 4. Integrated the furnace body and the temperature controller in one, the furnace is fixed on the temperature controller |
|||
Max. Temperature | 1000ºC | 1200ºC | ||
Continuous Temp. | 900ºC | 1100ºC | ||
Heating Rate | ≤15ºC/min (suggest 10ºC/min for longer life using of furnace) | |||
Heating Element | With the features of small volume, low energy consumption and light weight, the mini furnace is convenient for every person hold one set in the laboratory. It use electric resistance wire as heating element, adopted carbon steel shell structure and intelligent temperature control system; | |||
Chamber Material | 1. Adopt high quality alumina polycrystalline fiber, which used Japanese technology (vac-sorb forming alumina polycrystalline fiber) with good insulation and durability properties 2. High quality 1300 degree fiber alumina as refractory lining, pure white color 3. Ceramic fiber insulation for fast heat-up and reduced energy consumption-rise time to 1100°>C takes only 50 minutes. 4. Embedded heating elements on the round chamber which give an ideal temperature uniformity |
|||
Temp. Uniformity | ±5°C | |||
Thermocouple | N Type | |||
Temp. Controller | 1. Control system integrated in furnace base, Defined application within the constraints of the operating instructions 2. Furnace temperature controller utilizes PID technology for highly accurate 30-segment programmability 3. Feature single setpoint digital control, simultaneous LED display of actual temperature vs set point 4. A high-precision digital microprocessor controller fitted with self-tuning and manual PID settings makes temperature and other parameters easy to control 5. Temperature controller Precision ±1ºC |
|||
Electronics | SCHNEIDER maker air switch, buttons, solid-state relay, A.C contactor etc. | |||
Furnace Shell | 1. High quality cold-rolled steel sheets CNC processing 2. Environmental electrostatic plastic-spraying on surface after deoiling, derusting, phosphating etc. nine processes 3. Energy efficient insulation keeps exterior safe to touch |
|||
Safety Precautions | 1. Overheating & Broken thermocouple protection 2. Leakage circuit breaker 3. Automatic power off when furnace door opens (optional function) 4. Over-temperature protection and alarm allow for operation without attendant(s) 5. Microprocessor-based PID control with self-tuning capability to prevent overshooting of set temperature |
|||
Supply Scope | 1. One furnace body 2. One set of temperature controller system 3. Three-meter power line 4. One thermocouple 5. One pair of crucible stongs 6. One pair of high temperature furnace gloves 7. An instruction book |
|||
Optional Devices | Quartz Boat paperless recorder exhaust chimney |
|||
Warranty | One year limited manufacturer's warranty (Consumable parts such as processing tubes, O-rings and heating elements are not covered by the warranty, please order replacements at related products respectively |
Guarantee:
· One year, We provide permanent technology support.Warranty period appear quality problems free maintenance.After the warranty we need to replace parts we provide at cost price.
· Any technology question, we can provide video instruction, remote video instruction or fly to your country.
· Any problem we will handle in time within 24 hours
Quality
fessional QC team and every steps of processing we will strictly on quality.
· Our products will be conform international standards and has the CE certificate.
Servicing equipment during a breakdown is the worst possible scenario. System failure is unexpected, surprising and always at the wrong time. Alarge is prepared to deal with these situations. In order to raise the service reliability of your equipment, we offer comprehensive support services.
The engineering team at HIQ has the knowledge and experience to manage fleets of heat treating equipment in a planned and professional manner regardless of the equipment manufacturer. The solutions we offer are universal because they are based on best practices for failure prevention in the best sense of the word. Professional Technical Services provided by HIQ is more than the repair in case of failure. We understand how the equipment works and we increase uptime with the help of automated process maintenance that supports equipment architecture and technology solutions including renovation, modernization, and relocation services. Alarge carries out preventive inspections and the subsequent preventive measures using advanced tools in the field of metering and reporting.
You no longer have to worry about downtime and additional costs.
HIQ services are available around the clock, 7 days a week.
Suppliers with verified business licenses